  3. Section II. Using NAS-Data-Protection (D-NAS)
  4. Troubleshooting
  5. Restore from NAS array volume fails with the status: 174 Media manager - system error occurred.
NetBackup™ NAS Administrator's Guide

Restore from NAS array volume fails with the status: 174 Media manager - system error occurred.

Explanation:

This error occurs during granular restoration of a specific combination of files and directories that were backed up from a NAS array.

  • For NetBackup version 10.4, this issue occurs only for multi-stream restores.

  • For NetBackup version 10.5 and above, this issue occurs for both single-stream and multi-stream restores.

Workaround:

Do any of the following:

  • For NetBackup version 10.4, use a single stream for the restore job.

  • For NetBackup version 10.5 and above, do only one selection at a time, in the restore selection, like a volume, a directory, or individual file(s).

Feedback

Was this page helpful?
Previous

Error code: 930: No supported media server is available in the All_Media_Server_Pool to use to backup the NAS shares.

Next

NAS job fails with the error: Crawler process timed out after 600 seconds waiting for streams to attach with shared memory.

Feedback