Resiliency Platform fails to create storage policy
The clock time on IMS or Control Host and vSphere client is not synchronized.
Error message: Failed to perform operation. Log message in vsphere_spbmclient_pm.log: Client received SOAP Fault from server: The time now Day Month Date Time Zone Year does not fall in the request lifetime interval extended with clock tolerance of milliseconds. This might be due to a clock skew problem. See the server log to find more detail regarding exact cause of the failure.
Verify the following log files in IMS or Control Host server.
/var/opt/VRTSsfmh/logs/vsphere_spbmclient.log
/var/opt/VRTSsfmh/logs/vsphere_spbmclient_pm.log
Resolution: Ensure that the clock time on IMS or Control Host and vCenter server is synchronized and then re-run the workflow again.
If Veritas Replication Storage policy is not created automatically in Install/Upgrade Veritas Replication VIB operation, create Storage Policy named "vtstap" manually. The policy must include "vtstap" capability in the Common Rules section. For details on how to add a capability to storage policy, refer to VMware documentation on Storage Policy Based Management.