SYMSTAT_INTERVAL_SECONDS
Valid Values: Numeric in seconds (Default = See below)
Scope: This parameter can be set at the Data Collector level.
Used for EMC Symmetrix array performance collection.
Use this advanced parameter to gather more granular performance data. This parameter customizes the data collection interval. Use this in conjunction with the following.
See SYMSTAT_COUNT.
:
If these advanced parameters are not set, then the defaults are set to:
count = 1
interval is derived from the polling frequency of the performance probe.
The reason for using CLIENT is that in some cases the CIM server appears to not return all requested relationships. Using CLIENT will require more disk space on the collector (but not excessive - 10s or 100s of MB) and will tend to take longer before persisting at the start of collection, but less time at the end.