MMINFO_MOVE_BACKWARD_MIN
Valid Values: 0 or higher (Default = 30)
Scope: This parameter can be set at the Data Collector level.
This advanced parameter applies to NetWorker data collection. The data collection event thread runs every 10 minutes to get all the finished jobs that have been created after the last jobs that were captured during the last collection cycle, plus 30 minutes of additional time to account for long-running jobs.
For long-running backups, it may be necessary to configure the MMINFO_MOVE_BACKWARD_MIN Advanced Parameter to ensure that all NetWorker savesets are collected successfully. The default value is 30 minutes, but for long-running backups, that time may need to be adjusted because 30 minutes may not be long enough to capture all the jobs. For example, some jobs can last several hours.
Note that if a value of less than 30 minutes is configured, the Data Collector uses the default 30 minutes.