Ransomware attackers specifically target and attempt to destroy backup systems to increase the probability of payment. Hardening your system is critical. Please ensure you have reviewed your platform security using the Security Hardening Checklist
Cohesity

COHESITY Documentation

Explore our documentation to get started, discover products & new features, access troubleshooting guides, register sources, platforms support.

Products
Data Security Alliance
Visit Cohesity.com
Demos
Support
Blogs
Developers
Partner Portals
Cohesity Community
© 2026 Cohesity, Inc. All Rights Reserved.
Terms of Use|
Privacy Policy|
Legal|
  1. Home
  2. Veritas NetBackup™ Clustered Master Server Administrator's Guide
  3. NetBackup in a Windows Server Failover Clustering
  4. Installation prerequisites for NetBackup on WSFC cluster
Veritas NetBackup™ Clustered Master Server Administrator's Guide

Installation prerequisites for NetBackup on WSFC cluster

The following requirements must be met before you install and configure a NetBackup failover server in a WSFC environment:

  • Verify that WSFC and the current NetBackup version support your hardware. For a list of supported storage devices, visit the following Web site. Also consult the WSFC documentation.

    https://www.veritas.com/support/en_US/article.000033647

  • Verify that storage devices are properly installed and configured to work in a Windows environment. Refer to the information on configuring storage devices in the NetBackup Installation Guide.

    https://www.veritas.com/support/en_US/article.DOC5332

  • Verify that Windows Server Failover Clustering is correctly installed and configured. NetBackup can be installed on as many nodes as WSFC supports. WSFC supports up to 4 or 8 nodes in a cluster, depending on the level of Windows that is installed.

  • Physically connect the robotic devices and tape devices to each node where you want to install NetBackup). Connect devices by SCSI or Fibre Channel. Use OS commands to verify that all the devices are connected properly.

    See the NetBackup Device Configuration Guide.

    https://www.veritas.com/support/en_US/article.DOC5332

  • Verify that you have an IP address and host name (virtual name) to be assigned to the NetBackup cluster group. Use these only for the NetBackup cluster group.

    Also, verify that the disk resource is online on the node from which the NetBackup installation is about to be performed for the first time on the cluster.

    With this release IPv6 is supported with NetBackup.

  • Use Cluster Administrator to verify that the Possible Owners list for each disk resource that NetBackup uses includes each node to which NetBackup can failover.

  • Verify that you have the current NetBackup Enterprise Server version or the current NetBackup server version installation program and a valid license key.

  • The Windows Server Failover Clustering Administrator must be installed on all NetBackup servers that you use to administer the NetBackup failover master server remotely. Failover Cluster Manager must also be installed on any NetBackup administration clients.

  • You must have administrator rights or domain administrator credentials on the server cluster.

  • On Windows, the public network names must be the same on both nodes of the cluster for push installs.

  • You should install NetBackup on the same path on all the nodes.