Ransomware attackers specifically target and attempt to destroy backup systems to increase the probability of payment. Hardening your system is critical. Please ensure you have reviewed your platform security using the Security Hardening Checklist
Cohesity

COHESITY Documentation

Explore our documentation to get started, discover products & new features, access troubleshooting guides, register sources, platforms support.

Products
Data Security Alliance
Visit Cohesity.com
Demos
Support
Blogs
Developers
Partner Portals
Cohesity Community
© 2026 Cohesity, Inc. All Rights Reserved.
Terms of Use|
Privacy Policy|
Legal|
  1. Home
  2. NetBackup™ Status Codes Reference Guide
  3. Device management status codes
  4. Device management status codes
  5. Device management status code 41
NetBackup™ Status Codes Reference Guide

Device management status code 41

Message: Unknown drive name

Explanation: A request was made for a specified drive, but no such drive can be found in the active configuration. This status can occur in the following situations: if the device files are corrupt or missing, if they cannot be opened or read, or if there are no devices configured.

Recommended Action:

  • Ensure that ltid was stopped and restarted after changes were last made to the device configuration. (ltid is the Media Manager device daemon on UNIX and Linux or the NetBackup Device Manager service on Windows.) Display the device configuration (use the tpconfig -d command or other means) to see the list of valid drives. Specify the drive name or index as appropriate for the interface being used.

  • Check integrity of the EMM database. Display the device configuration to do the following:

    • Determine if the database is corrupt.

    • Restore a saved copy of the database file from catalog backups, or remove the devices and recreate the device configuration.