Robotic status code 202
Explanation:
An element of the robotic library device cannot be sensed. The cause can be any of the following:
The SCSI commands mode sense, mode select, or read element status (of slot, drive, transport, i/e element) may have failed.
A network API-controlled library inventory request may have failed.
The robotic daemon/process cannot initialize a robotic database file.
Recommended Action:
Check the configuration of the robot against the recommended configuration as indicated in the robot configuration documentation.
Check the health of the robotic device by using a robot test utility and then close the test utility when finished.
Check for the existence and permissions of the temporary robotic database and the temporary database directory/folder, which is
/usr/openv/volmgr/misc/robotic_db(UNIX and Linux) orinstall_path\Volmgr\misc\robotic_db(Windows). Create the directory/folder and adjust the permissions as needed so that the robotic daemon/process can create it or use it. Stop and restart ltid (the device daemon on UNIX and Linux or the NetBackup Device Manager service on Windows).