Ransomware attackers specifically target and attempt to destroy backup systems to increase the probability of payment. Hardening your system is critical. Please ensure you have reviewed your platform security using the Security Hardening Checklist
Cohesity

COHESITY Documentation

Explore our documentation to get started, discover products & new features, access troubleshooting guides, register sources, platforms support.

Products
Data Security Alliance
Visit Cohesity.com
Demos
Support
Blogs
Developers
Partner Portals
Cohesity Community
© 2026 Cohesity, Inc. All Rights Reserved.
Terms of Use|
Privacy Policy|
Legal|
  1. Home
  2. NetBackup™ Status Codes Reference Guide
  3. NetBackup status codes
  4. NetBackup status codes
  5. NetBackup status code: 207
NetBackup™ Status Codes Reference Guide

NetBackup status code: 207

Message: error obtaining date of last backup for client

Explanation: When nbpem tries to obtain the date of the last backup for a particular client, policy, and schedule combination, an error occurs.

Recommended Action: Do the following, as appropriate:

  • Verify that the NetBackup Database Manager, bpdbm, is running.

  • Examine the All Log Entries report for the appropriate time frame to gather more information about the failure.

  • For detailed troubleshooting information, create a bpdbm log directory on the master server. Increase the logging level for the diagnostic and debug logs for nbpem.

    Use the vxlogcfg command as explained in the following topic:

    See "About unified logging" in the NetBackup Logging Reference Guide.

    Retry the operation, then check the resulting logs.

Click here to view technical notes and other information on the Cohesity Technical Support website about this status code.

Feedback

Was this page helpful?
Previous

NetBackup status code: 206

Next

NetBackup status code: 209

Feedback

Was this page helpful?