About the CRC notifications for local LSU
NetBackup sends the notifications related to the status of CRC for local LSU. You can see these notifications on the NetBackup web UI. You can also use the NetBackup APIs to fetch these notifications. For more information about the APIs, see the NetBackup API documentation.
The CRC notifications for local LSU are enabled by default. You can disable it by using the EnableCRCDataScanNotification parameter.
See MSDP data integrity checking configuration parameters.
Table: CRC notifications
Notification | Type | Frequency | Configuration |
|---|---|---|---|
Some data scanned in the last 24 hrs | Information | Once every 24 hours. | Not configurable |
No data scanned in the last 24 hrs | Warning | Once every 24 hours. | Not configurable |
No data scanned in the last N days | Critical | Once every 24 hours. | Configurable |
Data corruption found | Critical | When the data corruption is found. The notification is not repeated more than once in 24 hours. | Not configurable |