Database Validation Check and Rebuild menu options
The Database Validation Check and Rebuild option lets you validate and rebuild the currently selected database.
Table: Database Validation Check and Rebuild menu options
Option | Description |
|---|---|
Standard Validation | The standard type of validation is not supported. This option performs a full validation. |
Full Validation | This option performs a database validation on all of the database tablespaces in the selected database.
Note: To perform a full database validation, shut down NetBackup and start only the database service. If any validation errors are reported, perform the following tasks:
If validation errors persist, contact Cohesity Technical Support. The administrator may be asked to rebuild the database using the Database Rebuild option or the nbdb_unload.exe command-line utility. |
Database Rebuild | This option lets you rebuild the database. A Database Rebuild results in a complete unload and reload of the database. A new database with all of the same options is built in place. A Database Rebuild may be required if Database Validation errors are reported using the Standard or Full Validation options. During a Database Rebuild, all NetBackup operations are suspended. When you select this option, a message appears which recommends that you exit and create a backup using the Backup Database option before you rebuild the database. You then have the choice of whether to continue or not. |
More Information