Huawei OceanStor V3
This information is provided to help with using NetBackup for NDMP with a Huawei OceanStor V3 system. For further details contact Huawei.
NDMP Settings are found in the Device Manager for the Huawei system: .
Once devices are connected to the system, run the following from the command line on the Huawei system to rescan for devices:
admin:/> change service ndmp_scanbus
Then, restart the NDMP service from the NDMP Settings window in the Device Manager.
File systems are presented over NDMP as /fs?, where "?" is the file system ID. To determine the available file systems use the following command:
admin:/>show file_system general
Available
ID Name ... Capacity ... Capacity ...
-- --------- ... --------- ... --------- ...
0 NFS100G1 ... 100.000GB ... 79.632GB ...
1 CIFS100G1 ... 100.000GB ... 79.576GB ...
2 NFS100G2 ... 100.000GB ... 79.632GB ... Note:
The ALL_FILESYSTEMS feature that was introduced in NetBackup 7.6 uses the NDMP_CONFIG_GET_FS_INFO NDMP command to get a list of file systems that the system presents over NDMP. The Huawei system supports this command, but it reports "/" as the only available file system. This is not a valid file system for use with NDMP. This means that the ALL_FILESYSTEMS and VOLUME_EXCLUDE_LIST file list directives are not supported with this system.