Post-migration tasks
After migration, if the name is changed to NetBackup Snapshot Manager, then perform the following steps for Linux and Windows on-host agent renews and then perform the plugin level discovery:
For Linux:
Edit the
/etc/flexsnap.conffile and update the targeted field with new IP/host of NetBackup Snapshot Manager.For example,
[root@testVM]# cat /etc/flexsnap.conf [global] target = nbuxqa-alphaqa-10-250-172-172.vxindia.veritas.com hostid = azure-vm-b5c2b769-256a-4488-a71d-f809ce0fec5d [agent] id = agent.c2ec74c967e043aaae5818e50a939556
Perform the Linux on-host agent renew using the following command:
/opt/VRTScloudpoint/bin/flexsnap-agent --renew --token <auth_token>
Restart Linux on-host agent using the following command:
sudo systemctl restart flexsnap-agent.service
For Windows:
Edit the
\etc\flexsnap.confand update the targeted field with new IP/host of NetBackup Snapshot Manager.For example,
[global] target = nbuxqa-alphaqa-10-250-172-172.vxindia.veritas.com hostid = azure-vm-427a67a0-6f91-4a35-abb0-635e099fe9ad [agent] id = agent.3e2de0bf17d54ed0b54d4b33530594d8
Perform the Windows on-host agent renew using the following command:
"c:\ProgramFiles\Veritas\CloudPoint\flexsnap-agent.exe" --renew --token <auth_token>