Connecting the fifth S Series storage shelf to an appliance
Note:
The cables in the following diagrams are shown in different colors for demonstration purposes only. The actual cables are black.
To connect the fifth storage shelves to an appliance
- Disconnect the SAS-3 cable from port A on the bottom I/O module on the fourth storage shelf and connect the cable to port A on the bottom I/O module of the fifth shelf.
The blue tab on the SAS cable in port A should be on the same side of the cable as the SAS label when connected.
- Connect one SAS-3 cable to port B in the top I/O module of the fourth storage shelf. Connect the other end of this cable to port A in the top I/O module in the fifth storage shelf.
The blue tab on the SAS cable in port A and port B should be on the same side of the cable as the SAS label when connected.
- Connect one SAS-3 cable to port A in the bottom I/O module of the fourth storage shelf. Connect the other end of this cable to port B in the bottom I/O module in the fifth storage shelf.
The blue tab on the SAS cable in port A and port B should be on the same side of the cable as the SAS label when connected.