Configuring an SNMP management server
To add an SNMP management server to receive SNMP traps
- To add an SNMP management server to receive SNMP traps, go to the Appliance CLISH and then go to Settings> Alerts. Run the SNMP Set <server name> command.
For more details, refer to the Veritas Access Appliance Command Reference Guide.
To display the current list of SNMP management servers
- To display the current list of SNMP management servers, enter the following:
Report> snmp show
To set the severity for SNMP traps to be sent
- To set the severity for SNMP traps to be sent, enter the following:
Report> snmp set severity value
where value indicates the severity for the SNMP trap to be sent.
To set the filter level of SNMP traps
- To set the filter level for SNMP traps, enter the following:
Report> snmp set filter value
where value indicates the filter.
To display the filter or the severity levels of SNMP traps to be sent
- To display the filter or the severity levels of SNMP traps to be sent, enter the following:
Report> snmp get filter|severity
To export the SNMP MIB file to a given URL
- To export the SNMP MIB file to a given URL, enter the following:
Report> snmp exportmib url
where url specifies the location the SNMP MIB file is exported to.
FTP and SCP URLs are supported.
- If the url specifies a remote directory, the default file name is
access_mib.txt.